Skip to content
Nanaimo Custom Bathrooms

Bathroom renovation services

Bathroom Flooring

Floor build-up planned as an assembly — subfloor prep, levelling, any heating layer — so thresholds and door clearances work out before the covering goes down.

Large format porcelain floor tile being laid over an electric underfloor heating mat

Floor build-up is planned as an assembly — subfloor prep, levelling, any heating layer — so thresholds and door clearances work out before the covering goes down.

  • Licensed & insured
  • WorkSafeBC coverage
  • Written quotes & contracts
  • Built to BC Building Code

What this covers

Bathroom Flooring

A bathroom floor is not a covering, it is a stack. Joists, subfloor, any levelling compound, an uncoupling or heating layer, adhesive, and the finished surface — each with its own thickness, and all of them adding up to a finished height that has to meet the hallway at the doorway, clear the door leaf, and land correctly against the shower entry. Get the arithmetic wrong and every remaining choice is a bad one: trim the door and leave a gap, add a threshold nobody wanted, or pack up a toilet flange to suit a floor that came up too high.

Start with what the floor is sitting on. Deflection is the first question. A tile floor needs a subfloor stiff enough that it does not flex underfoot, because tile and grout have essentially no tolerance for movement — the industry rule of thumb is a deflection limit of L/360 for ceramic and tighter still for natural stone. In older Nanaimo homes with 2x8 joists at 400mm centres over a long span, that limit is not automatic. Adding a second layer of subfloor, sistering joists or installing blocking is sometimes part of the scope, and it is far better identified at the measure than discovered when the grout cracks in a line down the middle of the room.

Levelling is separate from flatness. A floor can be level and not flat, or flat and not level, and tile cares about flatness while a freestanding tub cares about level. Self-levelling compound handles a floor that dishes or slopes; patching and grinding handle localised humps. Large format tile raises the standard considerably — a 600 x 1,200mm tile over an uneven floor produces lippage at every joint, and no amount of adhesive fixes it afterwards. The flatness tolerance is set by the tile format, so those two decisions are made together.

Heated floors are worth the coordination. Electric underfloor heating is one of the few upgrades people uniformly say they would do again, and on this coast it does real work — it takes the edge off a tiled floor in February and, more usefully, keeps the floor dry between uses in a climate where things stay damp. The system is a mat or loose cable laid in the adhesive bed or a levelling layer, with a floor sensor probe placed between the cable runs so it can be replaced later without lifting tile, and a dedicated circuit to a thermostat. It adds a few millimetres to the build-up, has to be laid out clear of the toilet flange and vanity footprint, must be resistance tested before, during and after tiling, and needs the electrical rough-in in place first. That is coordination rather than difficulty, but it has to happen in the right order.

Choosing the covering. Porcelain tile is the default in a bathroom: it is dense, effectively waterproof at the body, handles a heated floor well and lasts indefinitely. Its texture matters more than its pattern, because a polished porcelain floor in a wet room is a genuine slip risk and a matt or lightly textured surface with a reasonable coefficient of friction is the sensible choice — smaller formats help too, since the grout joints themselves provide grip. Natural stone is beautiful and demands sealing and a stiffer substrate. Luxury vinyl plank and sheet vinyl are warmer underfoot and more forgiving of an imperfect subfloor — sheet vinyl with welded seams, coved up the wall, is still the most watertight floor available and a serious option in a laundry or secondary bathroom. Laminate is the one to be careful with: even water-resistant laminate has a fibreboard core, so where it is wanted for continuity with an adjoining room, the perimeter and doorway detailing carries the weight.

Thresholds and transitions. The doorway is where the whole assembly is judged. A flush transition into an adjoining hardwood or carpeted floor looks right and is achievable when the build-up is planned in advance. A shower entry is a second transition with its own requirements, especially where it is curbless and the shower floor sits below the bathroom floor. Door undercut is checked against the finished height before the floor goes down, and the toilet flange is set at finished floor level so the seal works as intended.

The wet reality. Whatever the covering, water gets on a bathroom floor and eventually finds a joint. The perimeter is sealed flexibly rather than grouted, the junction at the tub or shower is a movement joint, and the area around the toilet — the most common source of slow, unnoticed leaks — is detailed so a failing seal shows itself rather than quietly soaking a subfloor for two years.

Why it matters

What you get

Finished height calculated first

Every layer in the stack is added up before ordering, so the doorway transition, the door undercut and the toilet flange height all work out.

Deflection checked, not assumed

Joist span, spacing and subfloor thickness are assessed against the stiffness tile requires, because movement is what cracks grout in a straight line.

Flatness matched to the tile format

Levelling is specified to the tolerance the chosen tile actually needs — large format demands a far flatter floor than small format does.

Heating laid out and tested properly

Cable runs are planned around the toilet flange and vanity, the sensor probe is placed so it can be replaced without lifting tile, and resistance is tested at each stage.

Slip resistance treated as a specification

Matt and textured surfaces with grout joints that provide grip, rather than a polished finish that looks well in a showroom and is a hazard when wet.

Perimeters and junctions detailed to move

Flexible joints at the perimeter, at the tub or shower junction and around the toilet, where slow leaks otherwise go unnoticed for years.

How it runs

The process

  1. 01

    Assess the existing floor

    Subfloor material and thickness, joist span and spacing, deflection, flatness and level are all recorded, along with the finished heights of adjoining floors.

  2. 02

    Design the build-up

    The full stack is specified — subfloor additions, levelling, heating layer, uncoupling, adhesive and covering — and totalled against the doorway and shower entry.

  3. 03

    Prepare and level

    Subfloor reinforcement is added where the span calls for it, then the surface is levelled or ground to the flatness the covering requires.

  4. 04

    Install heating and coordinate electrical

    Where a heated floor is included, the mat or cable is laid out, the sensor is placed in a replaceable position, and the dedicated circuit and thermostat are roughed in.

  5. 05

    Lay the covering

    Tile is set out from the most visible line, sheet or plank goods are laid with the seams placed away from the wettest zones, and cuts are worked to the room's geometry.

  6. 06

    Seal, transition and finish

    Perimeter and junction joints are sealed flexibly, thresholds are fitted, the door is checked for clearance and the toilet is reset to the finished height.

Plan the floor as an assembly, not a covering

Subfloor, levelling, heating and finish are totalled against the doorway and shower entry before anything is ordered.

Questions

Frequently asked

In a coastal climate it usually is, and not only for comfort. A heated floor keeps a tiled bathroom dry between uses, which matters here because ambient humidity stays high and floors stay damp. The running cost in a small bathroom on a thermostat with a timer is modest because the heated area is small and it only runs on a schedule. The main condition is that it has to be planned in — the circuit, the build-up height and the layout around the toilet and vanity all have to be settled before the floor goes down.

Sheet vinyl with welded seams and a coved edge up the wall is arguably the most watertight bathroom floor available and is a genuinely sensible choice, particularly in a secondary bathroom or laundry. Luxury vinyl plank is waterproof at the plank and depends on the perimeter detailing. Laminate is the one that needs care: even water-resistant products have a fibreboard core that swells if water sits in a joint, so where it is used for continuity with an adjoining room, the doorway and perimeter details do the work.

Not always. If the existing floor is sound, flat, at a workable height and the plumbing is not moving, it can sometimes stay — a vanity and top replacement over an existing tile floor is a common partial scope. It usually does come up when the toilet is being relocated, when the shower is being rebuilt, when the floor is not stiff or flat enough for the tile chosen, or when a heated floor is being added. The decision is made at the assessment rather than on the day of demolition.

Ideally nothing, because the finished height is calculated before anything is ordered. Where a build-up is unavoidable — adding a subfloor layer for stiffness, plus a levelling layer, plus a heating mat — the options are a threshold strip that takes up the difference over a short run, matching the adjoining floor up if it is also being replaced, or reducing the build-up by choosing a thinner covering. All of these are better as a decision made in advance than as a discovery at the doorway.

A matt or lightly textured porcelain, in a smaller rather than larger format. Slip resistance comes from surface texture and from grout joints, so a 300mm tile has meaningfully more grip than a 600 x 1,200mm one with the same finish, and a mosaic more again — which is part of why mosaics are common on shower floors. Polished porcelain and polished stone look striking dry and are a real hazard wet. Where large format is wanted for appearance, a textured or structured finish is the compromise worth making.